Continuous level meter (4-20mA)

– Continuous level meter
– float technology
– Output signal 4-20mA (on request)
– Vertical mounting
– Customized materials / dimensions
– MI.SA approval (on request)
– ATEX approval (on request)

Showing all 14 results

  • INFO-TECH

    INFO-TECH – Potentiometric Level meter

    – General technical information

    Data sheet


  • LINEAR-O

    LINEAR – O

    – Brass
    – Accuracy 5 – 10 – 20 mm.
    – Potentiometric output (LC)
    – Analog output 4-20mA (LCT)
    – Voltage output 0-5 / 0-10V (LCTV)
    – Local indicator display (0)4-20mA (LCO)
    – Length up to 6 m.
    – Max working pressure up to 20 Bar
    – Max ambient temperature -30/+55°C, UR 90%
    – Standard working temperature up to 105°C
    – Special version for temperature 120°C on request
    – IP65 protection
    – On request integrated temperature sensor type :
    PT – PTC – NTC

    Data sheet


  • LINEAR-S

    LINEAR – S

    – St. Steel ─ AISI 316
    – Accuracy 5 – 10 – 20 mm.
    – Potentiometric output (LC)
    – Analog output 4-20mA (LCT)
    – Voltage output 0-5 / 0-10V (LCTV)
    – Local indicator display (0)4-20mA (LCO)
    – Length up to 6 m.
    – Max working pressure up to 50 Bar
    – Max ambient temperature -30/+55°C, UR 90%
    – Standard working temperature up to 105°C
    – Special version for temperature 150°C on request
    – IP65 protection
    – On request integrated temperature sensor type :
    PT – PTC – NTC

    Data sheet


  • LINEAR-V-F

    LINEAR – V-F

    – PVC – PP – PVDF
    – Accuracy 5 mm.
    – Potenziometric signal output (LC)
    – Analog output 4-20mA (LCT)
    – Voltage output 0-5 / 0-10V (LCTV)
    – Local indicator display (0)4-20mA (LCO)
    – Length up to 5 m
    – Max working pressure 6 bar
    – Max ambient temperature -30/+55°C UR 90%
    – Max working temperature up to 130°C
    – IP65 protection
    – On request integrated temperature sensor type:
    PT – PTC – NTC

    Data sheet


  • LINEAR-MISA_1

    LINEAR – MISA

    – Approved in accordance with:
    – Fire Prevention Safety Standard
    – MI.SA Circ. 31.8.78 N.31 – Fire section
    – Potentiometric output (LC)
    – Analog output 4-20mA (LCT)
    – Length up to 6 meters
    – Materials: Brass – Spansil – St. steel
    – Pmax = up to 40 bar (see data sheet)
    – Tmax = 105°C – 120°C or 150°C on request
    – Protection class IP65

     

    Data sheet


  • INFO-TECH

    INFO-TECH – Magnetostrictive Level meter

    – General technical information

    Download pdf


  • LINEAR_LCM_O

    LINEAR – LCM – O

    – Magnetostrictive technology
    – Brass material
    – 1 analog output, current or voltage.
    – 2 analog outputs, current and voltage.
    – 2 factory programmable PNP digital outputs.
    – RS485 serial output, Valco protocol.
    – Programming via dedicated handheld computer VSP.130, on request
    – Up to 2, 9 m length.
    – Working pressure up to 50 bars depending on the used float.
    – Operating ambient temperature -30 / +70 °C, RH 90%.
    – Standard working temperature up to 105 °C
    150 °C working temperature on request.
    – Minimum degree of protection IP67

    Data sheet


  • LINEAR_LCM_S

    LINEAR – LCM – S

    – Magnetostrictive technology
    – Stainless steel ─ AISI 316
    – 1 analog output, current or voltage.
    – 2 analog outputs, current and voltage.
    – 2 factory programmable PNP digital outputs.
    – RS485 serial output, Valco protocol.
    – Programming via dedicated handheld computer VSP.130, on request
    – Up to 2, 9 m length.
    – Working pressure up to 50 bars depending on the used float.
    – Operating ambient temperature -30 / +70 °C, RH 90%.
    – Standard working temperature up to 105 °C
    150 °C working temperature on request.
    – Minimum degree of protection IP67

    Data sheet


  • LINEAR_LCM_VF

    LINEAR – LCM – V-F

    – Magnetostrictive technology
    – PVC – PP – PVDF
    – 1 analog output, current or voltage.
    – 2 analog outputs, current and voltage.
    – 2 factory programmable PNP digital outputs.
    – RS485 serial output, Valco protocol.
    – Programming via dedicated handheld computer VSP.130, on request.
    – Up to 2, 9 m length.
    – Working pressure up to 6 bar depending on the used float.
    – Operating ambient temperature -30 / +70 °C, RH 90%.
    – Working temperature up to 130 °C
    – Minimum degree of protection IP67

    Data sheet


  • INFO-TECH

    INFO-TECH – Capacitive level meter

    – General technical information

    Download pdf


  • LINEAR-LCV

    LINEAR – LCV

    – Capacitive technology
    – Measuring ranges 100 3000 mm
    – Accuracy ±0,5% of measured value (±2 mm).
    – Programming via the front panel keypad and LCD display.
    – Additional Teach-in function.
    – Measuring units programmable in linear values or %.
    – Signal indication with 2 three-color LED.
    – NPN output with short-circuit protection programmable NO or NC.
    – 0 ÷ 10 V or 4-20mA analog output.
    – Operating temperature range -25/+70°C.
    – Degree of protection IP65

    Data sheet


  • INFO-TECH

    INFO-TECH – Ultrasonic Level meter

    – General technical information

    Download pdf


  • LINEAR-VLS

    LINEAR – VLS

    – Ultrasonic technology
    – Measuring ranges from 30 ! 350 mm to 600 ! 8000 mm
    – Resolution 0,18 mm
    – Repeatability ± 0,15%
    – Programming via 2 push-buttons and visualization on 3 digit LED display.
    – Additional Teach-in function.
    – Measuring units programmable in mm, cm, or %
    – Signal indication with 2 three-color LED.
    – PNP output with short-circuit protection programmable NO or NC.
    – 0 ÷ 10 V or 4-20mA analog output.
    – Operating temperature range -25/+70°C.
    – Degree of protection IP67

    Data sheet


  • VLC_602_M

    MULTISIGNAL – VLC.602

    – Programmable range and measuring units
    – LCD display, 16 digit, illuminated
    – Input:
    – 0(4)-20mA, 0-5(10)V, 5-2000Hz, 0,5-20Kohm
    – Output 0(4)-20mA, 0-5(10)V
    – Supply voltage 24/220Vac, 24Vdc on request
    – N.2 output alarm relays, N.6 relays (option)
    – Alarm LED indication
    – Panel mounting construction
    – Protection class IP40

    Data sheet