Flow Meter

– Rotor flow meter
– Volumetric flow meter
– Flow rate meter – variable area
– Local flow indicator

Showing all 15 results

  • INFO-TECH

    INFO-TECH — Flow Transmitters / Flow Meters

    – General technical information

     

    Data sheet


  • METER_XF

    METER – XF

    – Flexible disk type – innovation sensing element
    – Separation between the flow chamber and electrical components
    – Plastic or metal construction body
    – Process connections from 1/4″ to 1″ Gas-F
    – Measuring range 1:80
    – High accuracy and fast response time
    – Low pressure loss
    – PNP-NPN or 4-20 mA or 0-10V or Frequency outputs
    – Pmax = up to 100 bar (see data sheet)
    – Tmax = 70°C – 150°C on request
    – Protection class IP67

     
    Data sheet


  • METER_RR

    METER – RR

    – Rotor type
    – Liquids application only
    – Nickel plated Brass – St. Steel – POM – PVDF materials
    – Process connection 3/8” to 1” Gas-F
    – Measuring range from 0,1 to 100 l/min. (H2O)
    – NPN or PNP output, square wave frequency signal
    – 1% accuracy
    – Pmax = 100 bar (see data sheet)
    – Tmax= 100°C (see data sheet)
    – Protection class IP67

     

    Data sheet


  • METER_RR032

    METER – RR032

    – Rotor type for pipe size from DN32 to DN100
    – Liquids application only
    – PVC or St. Steel materials
    – 1.1/4″ Gas-F cap process connections
    – 1/2″ Gas-M adapter on request
    – Measuring range from 30 to 1000 l/min. (H2O)
    – NPN or PNP output, square wave frequency signal
    – 3% accuracy
    – Pmax = up to 100 bar (see data sheet)
    – Tmax = up to 100°C (see data sheet)
    – Protection class IP67

     

    Data sheet


  • METER_RT

    METER – RT

    – Turbine type
    – Liquids application only
    – St. Steel material
    – Process connection 1/2” to 2” Gas-M
    – Measuring range from 0,11 to 68 m3/h (H2O)
    – NPN or PNP output, square wave frequency signal
    – 4-20mA output on request
    – 1% accuracy
    – Pmax = 250 bar
    – Tmax= 85°C
    – Protection class IP67

     

    Data sheet


  • METER_TCV_TCO

    METER – TCV / TCO

    – Propeller type
    – Bidirectional operation
    – Liquids application only
    – Latene body – Glass viewer pipe
    – Brass or St. Steel connections materials
    – Process connections from 3/8″ to 1″ Gas-F
    – Measuring range from 3 to 80 l/min. (H2O)
    – PNP or NPN output, square wave frequency signal
    – 3% accuracy
    – Pmax = 10 bar
    – Tmax = 100°C
    – Protection class IP67

     

    Data sheet


  • METER_AFM

    METER – AFM

    – Turbine type
    – Liquids application only
    – Fully PVDF construction
    – Flexible hose fitting or 1/4″ to 1.1/4″ male connections
    – Measuring range from 0,1 to 120 l/min (H2O)
    – Square or sinusoidal wave frequency output signal
    – Accuracy 1% of the measured value
    – Repeatability 0,1%
    – Pmax = 6 bar
    – Tmax = 80°C
    – Protection class IP65

     

    Data sheet


  • METER_OMNI_F

    METER – OMNI-F

    – Calorimetric type
    – Liquids application only
    – St. Steel material
    – Process connection 1/2” Gas-M – other on request
    – No moving parts
    – Measuring range from 1 to 150 cm/sec. (H2O)
    – 0(4)-20mA output
    – N.2 adjustable set points
    – 10% accuracy
    – LCD illuminated graphic display
    – Pmax = 200 bar
    – Tmax= 70°C
    – Protection class IP67

    Data sheet


  • METER_FLEX_FIN

    METER – Flex-Fin

    – Calorimetric type – low flow measurement
    – Liquids application only
    – St. Steel material
    – Smooth pipe crimp connections or flexible
    – No moving parts
    – Measuring range from 0,001 to 10 l/min. (H2O)
    – 0(4)-20mA or 0-10V output
    – N.1 adjustable set point
    – 3% accuracy – 1% repeatibility
    – Temperature signal output on request
    – Pmax = 10 bar
    – Tmax= 70°C
    – Protection class IP65

     

    Data sheet


  • METER_VHS

    METER – VHS

    – Screw volumetric type
    – Viscous liquids application
    – Bidirectional operation
    – Aluminum or St. Steel body
    – Process connections from 1″ to 2.1/2″ Gas-F
    – Measuring range from 1,4 to 2500 l/min.
    – 1% accuracy of the measured value
    – 0,25% repeatibility
    – PNP-NPN output, 4-20 mA or 0-10V on request
    – Pmax = up to 350 bar (see data sheet)
    – Tmax = 80°C – 150°C on request
    – Protection class IP65

     

    Data sheet


  • METER_VHZ

    METER – VHZ

    – Gear wheel volumetric type
    – Viscous liquids application
    – Aluminum or St. Steel body
    – Process connections from 1/4″ to 1″ Gas-F
    – Measuring range from 0,02 to 150 l/min.
    – Viscosity application range up to 20000 Cst
    – 3% accuracy
    – PNP or NPN output, square wave frequency signal
    – Pmax = up to 200 bar (see data sheet)
    – Tmax = 80°C
    – Protection class IP65

     

    Data sheet


  • METER_UK

    METER – UK

    – Variable area float type
    – Liquids and gas application
    – Acrylic body
    – Process connections 1/8″ Gas-F, brass or St. Steel
    – Measuring ranges:
    – Air = 0,04 – 100 Nl/min.
    – H2o = 0,2 – 220 L/h
    – Adjustment flow valve on request
    – Pmax = 6 bar
    – Tmax = 65°C

     

    Data sheet


  • METER_UK047

    METER – UK.047

    – Variable area float type
    – Liquids and gas application
    – Acrylic body
    – Process PVC connections 1/2″ Gas-F
    – Measuring ranges:
    – Air = 80 – 340 Nl/min
    – H2o = 2 – 40 l/min
    – Dual scale: liters minute/hour
    – Pmax = 6 bar
    – Tmax = 65°C

     

    Data sheet


  • METER_UK050

    METER – UK.050

    – Variable area float type
    – Liquids and gas application
    – Acrylic body
    – Process PVC connections 1″ Gas-F
    – Measuring ranges:
    – Air = 100 – 3000 Nl/min
    – H2o = 1 – 75 l/min
    – Adjustment flow valve on request
    – Pmax = 6 bar
    – Tmax = 65°C

     

    Data sheet


  • METER_TZ

    METER – TZ1

    – Piston-Float disc type
    – Liquids application only
    – Local indication – dry graduated scale
    – Nickel plated Bronze or St. Steel body
    – Process connections from 1/4″ to 3″ Gas-F
    – Flanged up to DN300 on request
    – Measuring ranges from 2 to 600 l/min.
    – SPDT mcro-switch 250Vac – 6A on request
    – Pmax = up to 100 bar (see data sheet)
    – Tmax = 90°C
    – Protection class IP65

     

    Data sheet